Features
- Remote gas leakage measurement without contact
- Detection distance exceeding 150 meters
- Compact and lightweight design for easy portability
- High selectivity, responds exclusively to Methane
- Sensitivity down to 5 ppm.m
- Rapid response with no alarm delay
- Minimal zero drift
- Colour LCD screen with adjustable brightness
- Display includes waveform graph and digital readout
- Incorporates spotter beam for enhanced visibility over long distances
Technical specifications
| Gas | CH4 |
| Principle | TDLAS |
| Distance | 590.55 in (150 m) |
| Response time | T90 < 0.05 S |
| Explosion-proof grade | Ex ib IIC T4 Gb |
| Power supply | DC 3.7 V rechargeable Lithium battery |
| Working time | 8 hours continuously |
| Display | Colour LCD screen |
| Lifespan | 10 years |
| Alarming method | Visual & audible alarm |
| Alarm threshold | Adjustable |
| Penetrating | An object that can be penetrated by light |
| Detection range | 0 ppm to 100000 ppm |
| Sensitivity | 5ppm |
| Data transmission | Blue tooth |
| Accessory | Battery Charger, wrist band |
| Humidity | <99% RH (no condensation) |
| Ingress protection | IP 66 |
| Storage temperature | -4 °F to 140 °F (-20 ℃ to 60 ℃) |
| Working temperature | -22 °F to 122 °F (-30 ℃ to 50 ℃) |
| Weight | 1.32 lb (600 g) |









Reviews